LED Street Lights,Street Lamp,LED Street Lamp LED Bulb Light Bracket Co., Ltd. , http://www.challleds.com
Original Meanwell LPV-60 Series Single Output Waterproof IP67 LED Driver Features:
1. Constant voltage design
2. Universal AC input / Full range
3. Withstand 300VAC surge input for 5 seconds
4. Protections: Short circuit / Over load / Over voltage
5. Cooling by free air convection
6. Small and compact size
7. Fully encapsulated with IP67 level (Note.7)
8. Fully isolated plastic case
9. Class 2 power unit, no FG, Class 2 power unit
10. Pass LPS
11. Suitable for LED Lighting and moving sign applications
12. 100% full load burn-in test
13. Low cost, high reliability
14. 2 years warranty
Original Meanwell LPV-60 Series Single Output Waterproof IP67 LED Driver Specifications:
Â
MODEL
LPV-60-5
LPV-60-12
LPV-60-15
LPV-60-24
LPV-60-36
LPV-60-48
OUTPUT
DC VOLTAGE
5V
12V
15V
24V
36V
48V
RATED CURRENT
8A
5A
4A
2.5A
1.67A
1.25A
CURRENT RANGE
0 ~ 8A
0 ~ 5A
0 ~ 4A
0 ~ 2.5A
0 ~ 1.67A
0 ~ 1.25A
RATED POWER
40W
60W
60W
60W
60W
60W
RIPPLE & NOISE (max.) Note.2
80mVp-p
120mVp-p
120mVp-p
150mVp-p
150mVp-p
150mVp-p
VOLTAGE TOLERANCE Note.3
±8.0%
±5.0%
LINE REGULATION
±1.0%
LOAD REGULATION
±6.0%
±2.0%
SETUP, RISE TIMEÂ Â Â Â Â Â Â Note.6
500ms, 20ms / 230VAC 500ms, 20ms / 115VAC at full load(for 5~36V) ; 500ms, 30ms / 230VAC 500ms, 30ms / 115VAC at full load(for 48V)
HOLD UP TIME (Typ.)
50ms/230VACÂ Â Â 16ms/115VAC at full load
INPUT
VOLTAGE RANGEÂ Â Â Â Â Â Â Â Note.4
90 ~ 264VACÂ Â Â 127 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY (Typ.)
76%
83%
83%
86%
86%
86%
AC CURRENT (Typ.)
1.2A/115VAC 1A/230VAC
INRUSH CURRENT(Typ.)
COLD START 60A(twidth=525μs measured at 50% Ipeak) at 230VAC
MAX. No. of PSUs on 16A
3 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT
0.25mA / 240VAC
PROTECTION
OVER LOAD
110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE
5.75 ~ 6.75V
13.8 ~ 16.2V
17.25 ~ 20.25V
27.6 ~ 32.4V
41.4 ~ 48.6V
55.2 ~ 64.8V
Protection type : Shut down o/p voltage, re-power on to recover
ENVIRONMENT
WORKING TEMP.
-30 ~ +70ºC (Refer to "Derating Curve")
WORKING HUMIDITY
20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY
-40 ~ +80ºC, 10 ~ 95% RH
TEMP. COEFFICIENT
±0.03%/ºC (0 ~ 50ºC)
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY &
EMCSAFETY STANDARDS
UL879(except for LPV-60-5), UL1310(except for LPV-60-5), CSA C22.2 No. 207-M89(except for LPV-60-5, LPV-60-48),
CAN/CSA C22.2 No. 223-M91(except for LPV-60-5,LPV-60-48), IP67, IEC60950-1:2005+A2:2013 approved ; design refer to TUV EN60950-1
WITHSTAND VOLTAGE
I/P-O/P:3KVAC
ISOLATION RESISTANCE
I/P-O/P:>100M Ohms / 500VDC / 25ºC/ 70% RH
EMC EMISSION
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2 Class A, EN61000-3-3
EMC IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A
OTHERS
MTBF
732Khrs min. MIL-HDBK-217F (25ºC)
DIMENSION
162.5*42.5*32mm (L*W*H)
PACKING
0.4Kg; 32pcs/13.8Kg/0.56CUFT
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
7. The unit might not be suitable for lighting applications in EU countries. Please check with your local authorities for the possible use of the unit.
8. Suitable for indoor use or outdoor use without direct sunlight exposure. Please avoid immerse in the water over 30 minute.
Â
Â