What should I do with grating error?

1. When the grating scale sensor and the digital meter plug socket are plugged in and out, the power should be turned off.

2. As far as possible, add a protective cover, timely clean the cutting and oil splashing on the ruler, and strictly prevent any foreign matter from entering the inside of the housing.

3. Check regularly for loose connection screws.

4. To extend the life of the dust seal, apply a thin layer of silicone oil to the seal. Be careful not to splash on the etched surface of the glass grating.

5. In order to ensure the reliability of the use of the scale sensor, it is possible to clean the rubbed grating surface and the indicator grating surface with an alcohol mixture (50% each) at regular intervals to keep the glass scale surface clean.

6. The grating scale sensor is forbidden to shake and beat violently so as not to damage the grating ruler. If the grating ruler breaks, the grating ruler sensor will fail.

7. Do not disassemble the grating scale sensor by yourself, nor change the relative distance between the main grating and the sub grating. Otherwise, on the one hand, the accuracy of the grating scale sensor may be damaged. On the other hand, the relative rubbing between the main scale and the sub scale may be caused, and the chromium may be damaged. The layer also destroys the grid lines, causing the grating rule to be scrapped.

8. Care should be taken to prevent oil stains and water contamination on the scale surface, so as not to damage the stripe distribution of the scale lines and cause measurement errors.

9. The grating scale sensor should try to avoid working in the severe corrosive environment, so as not to erode the surface of the grating chromium scale and scale, and destroy the quality of the grating scale.

Sming Wei Technology main products are linear displacement sensor (electronic ruler), pull rope displacement sensor, magnetostrictive displacement sensor (non-contact displacement sensor), grating displacement sensor (linear scale), LVDT displacement sensor, load cell, liquid It includes all kinds of digital display meters and automation equipments, and has a complete range of products. At the same time, it provides design, construction, installation and commissioning services for low-voltage electrical and PLC process control systems. The products are now widely used in the field of automated measurement and control in all walks of life.

All In One System

Shenzhen Enershare Technology Co.,Ltd , https://www.enersharepower.com