Medium Voltage 6/35kv XLPE Insulated Unarmoured Power Cable

Model NO.: YJV
No.of Cores: 1-5 Cores
Applicable Standard: IEC60502 IEC60331 DIN BS
Certificate: SABS, ISO9001-2008, CQC Certificate, CE , SGS
Trademark: Jiapu
Transport Package: Wooden Drums or Iron-Wooden Drums
Specification: IEC ASTM BS DIN
Origin: Henan China
HS Code: 4101962331
Model NO.: YJV
No.of Cores: 1-5 Cores
Applicable Standard: IEC60502 IEC60331 DIN BS
Certificate: SABS, ISO9001-2008, CQC Certificate, CE , SGS
Trademark: Jiapu
Transport Package: Wooden Drums or Iron-Wooden Drums
Specification: IEC ASTM BS DIN
Origin: Henan China
HS Code: 4101962331
Medium Voltage 6/35KV XLPE Insulated Unarmoured Power Cable

Application:
Media Voltage XLPE Insulated power cable is used to transmit and distribute power in power transmission and distribution system of 35kV or lower. It is generally applied to the fields including power, construction, mines, metallurgy, petrochemical industry and communication in complete replace of oil immersed paper insulated power cable.

Property:
1.The highest allowed operating temperature of conductor for long-term working is 90 degrees.
2.In short circuit (Max long term is no more than 5 seconds). The highest temperature for conductor is no more than 250 degrees.
3.The cable is laid without horizontal drop limit. The environment temperature should be no lower than 0 when lay. Otherwise it should be preheated.
4.Excellent electrical performance, resistance to chemical corrosion.
5.They can stand advisable traction when laid.They can stand traction from Outside.Left low smoke halogen-free after burned.Retard the burning of the cable.

Specification:

Standard:
IEC60502,designing and manufacturing special power cable according to the other standards required by the customers.
1) 3.6/6(7.2)kV,3.6/6.6(7.2)kV,Single Core,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable

Normal Cross Section of Conductor

Normal Diameter of Conductor

Normal Thickness of Insulation

Normal Thickness of
Copper Tape

Normal Thickness of Outer Sheath

Approx.
Overall Dia.

Approx. Net Weight

Max. D.C. Resistance of Conductor at 20ºC

Al Conductor

Cu Conductor

Al Conductor

Cu Conductor

mm2

mm

mm

mm

mm

mm

kg/m

kg/m

Ω/km

Ω/km

25

6.0

2.5

0.12

1.5

17.6

0.34

0.49

1.2000

0.7270

35

7.0

2.5

0.12

1.5

18.5

0.39

0.60

0.8680

0.5240

50

8.3

2.5

0.12

1.6

20.0

0.46

0.74

0.6410

0.3870

70

9.7

2.5

0.12

1.6

21.5

0.55

0.96

0.4430

0.2680

95

11.3

2.5

0.12

1.7

23.3

0.66

1.23

0.3200

0.1930

120

13

2.5

0.12

1.7

24.8

0.77

1.48

0.2530

0.1530

150

14.6

2.5

0.12

1.8

26.4

0.87

1.77

0.2060

0.1240

185

15.9

2.5

0.12

1.8

28.1

1.01

2.13

0.1640

0.0991

240

18.3

2.6

0.12

1.9

30.9

1.23

2.71

0.1250

0.0754

300

20.4

2.8

0.12

2.0

33.6

1.48

3.32

0.1000

0.0601

400

23.2

3.0

0.12

2.1

37.0

1.81

4.16

0.0778

0.0470

500

26.4

3.2

0.12

2.2

41.1

2.24

5.27

0.0605

0.0366

630

30.1

3.2

0.12

2.3

45.0

2.73

6.62

0.0469

0.0283


2) 6/10(12)kV,6.35/11(12)kV,Single Core,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable

Normal Cross Section of Conductor

Normal Diameter of Conductor

Normal Thickness of Insulation

Normal Thickness of
Copper Tape

Normal Thickness of Outer Sheath

Approx.
Overall Dia.

Approx. Net Weight

Max. D.C. Resistance of Conductor at 20ºC

Al Conductor

Cu Conductor

Al Conductor

Cu Conductor

mm2

mm

mm

mm

mm

mm

kg/m

kg/m

Ω/km

Ω/km

25

6.0

3.4

0.12

1.5

19.4

0.40

0.55

1.2000

0.7270

35

6.9

3.4

0.12

1.6

20.5

0.45

0.66

0.8680

0.5240

50

8.2

3.4

0.12

1.6

21.8

0.52

0.80

0.6410

0.3870

70

9.7

3.4

0.12

1.7

23.5

0.62

1.03

0.4430

0.2680

95

11.3

3.4

0.12

1.7

25.1

0.73

1.30

0.3200

0.1930

120

12.8

3.4

0.12

1.8

26.8

0.85

1.56

0.2530

0.1530

150

14.2

3.4

0.12

1.8

28.2

0.95

1.85

0.2060

0.1240

185

15.9

3.4

0.12

1.9

30.1

1.10

2.22

0.1640

0.0991

240

18.3

3.4

0.12

2.0

32.7

1.33

2.80

0.1250

0.0754

300

20.4

3.4

0.12

2.0

34.8

1.54

3.39

0.1000

0.0601

400

23.2

3.4

0.12

2.2

38.0

1.87

4.22

0.0778

0.0470

500

26.4

3.4

0.12

2.2

41.5

2.26

5.29

0.0605

0.0366

630

30.1

3.4

0.12

2.4

45.6

2.78

6.67

0.0469

0.0283


3) 8.7/10(15)kV,Single Core,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable

Normal Cross Section of Conductor

Normal Diameter of Conductor

Normal Thickness of Insulation

Normal Thickness of
Copper Tape

Normal Thickness of Outer Sheath

Approx.
Overall Dia.

Approx. Net Weight

Max. D.C. Resistance of Conductor at 20ºC

Al Conductor

Cu Conductor

Al Conductor

Cu Conductor

mm2

mm

mm

mm

mm

mm

kg/m

kg/m

Ω/km

Ω/km

25

6.0

4.5

0.12

1.6

21.8

0.48

0.63

1.2000

0.7270

35

6.9

4.5

0.12

1.7

22.9

0.54

0.75

0.8680

0.5240

50

8.2

4.5

0.12

1.7

24.2

0.61

0.89

0.6410

0.3870

70

9.7

4.5

0.12

1.8

25.9

0.72

1.13

0.4430

0.2680

95

11.3

4.5

0.12

1.8

27.5

0.84

1.40

0.3200

0.1930

120

12.8

4.5

0.12

1.9

29.2

0.96

1.67

0.2530

0.1530

150

14.2

4.5

0.12

1.9

30.6

1.06

1.96

0.2060

0.1240

185

15.9

4.5

0.12

2.0

32.5

1.22

2.34

0.1640

0.0991

240

18.3

4.5

0.12

2.1

35.1

1.46

2.93

0.1250

0.0754

300

20.4

4.5

0.12

2.1

37.2

1.68

3.52

0.1000

0.0601

400

23.2

4.5

0.12

2.2

40.2

2.00

4.35

0.0778

0.0470

500

26.4

4.5

0.12

2.3

43.9

2.43

5.45

0.0605

0.0366

630

30.1

4.5

0.12

2.4

47.8

2.93

6.83

0.0469

0.0283


4) 12/20(24)kV, 12.7/22(24)kV,Single Core,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable

Normal Cross Section of Conductor

Normal Diameter of Conductor

Normal Thickness of Insulation

Normal Thickness of
Copper Tape

Normal Thickness of Outer Sheath

Approx.
Overall Dia.

Approx. Net Weight

Max. D.C. Resistance of Conductor at 20ºC

Al Conductor

Cu Conductor

Al Conductor

Cu Conductor

mm2

mm

mm

mm

mm

mm

kg/m

kg/m

Ω/km

Ω/km

25

 

 

 

 

 

 

 

 

 

35

6.9

5.5

0.12

1.7

24.9

0.62

0.83

0.8680

0.5240

50

8.2

5.5

0.12

1.8

26.4

0.70

0.98

0.6410

0.3870

70

9.7

5.5

0.12

1.8

27.9

0.80

1.21

0.4430

0.2680

95

11.3

5.5

0.12

1.9

29.7

0.94

1.50

0.3200

0.1930

120

12.8

5.5

0.12

1.9

31.2

1.05

1.77

0.2530

0.1530

150

14.2

5.5

0.12

2.0

32.8

1.17

2.07

0.2060

0.1240

185

15.9

5.5

0.12

2.0

34.5

1.33

2.45

0.1640

0.0991

240

18.3

5.5

0.12

2.1

37.1

1.57

3.04

0.1250

0.0754

300

20.4

5.5

0.12

2.2

39.4

1.81

3.66

0.1000

0.0601

400

23.2

5.5

0.12

2.3

42.4

2.14

4.49

0.0778

0.0470

500

26.4

5.5

0.12

2.4

46.1

2.58

5.61

0.0605

0.0366

630

30.1

5.5

0.12

2.4

49.8

3.10

6.99

0.0469

0.0283


5) 18/30(36)kV,19/33(36)kV,Single Core,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable

Normal Cross Section of Conductor

Normal Diameter of Conductor

Normal Thickness of Insulation

Normal Thickness of
Copper Tape

Normal Thickness of Outer Sheath

Approx.
Overall Dia.

Approx. Net Weight

Max. D.C. Resistance of Conductor at 20ºC

Al Conductor

Cu Conductor

Al Conductor

Cu Conductor

mm2

mm

mm

mm

mm

mm

kg/m

kg/m

Ω/km

Ω/km

25

 

 

 

 

 

 

 

 

 

35

 

 

 

 

 

 

 

 

 

50

8.2

8.0

0.12

2.0

31.8

0.95

1.23

0.6410

0.3870

70

9.7

8.0

0.12

2.0

33.3

1.07

1.47

0.4430

0.2680

95

11.3

8.0

0.12

2.1

35.1

1.21

1.78

0.3200

0.1930

120

12.8

8.0

0.12

2.1

36.6

1.34

2.05

0.2530

0.1530

150

14.2

8.0

0.12

2.2

38.2

1.47

2.37

0.2060

0.1240

185

15.9

8.0

0.12

2.2

39.9

1.64

2.76

0.1640

0.0991

240

18.3

8.0

0.12

2.3

42.5

1.90

3.37

0.1250

0.0754

300

20.4

8.0

0.12

2.4

44.8

2.16

4.01

0.1000

0.0601

400

23.2

8.0

0.12

2.4

47.6

2.52

4.87

0.0778

0.0470

500

26.4

8.0

0.12

2.5

51.3

2.98

6.01

0.0605

0.0366

630

30.1

8.0

0.12

2.6

55.2

3.54

7.43

0.0469

0.0283


6) 3.6/6(7.2)kV,3.6/6.6(7.2)kV,Three Cores,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable

Normal Cross Section of Conductor

Normal Diameter of Conductor

Normal Thickness of Insulation

Normal Thickness of
Copper Tape

Normal Thickness of Outer Sheath

Approx.
Overall Dia.

Approx. Net Weight

Max. D.C. Resistance of Conductor at 20ºC

Al Conductor

Cu Conductor

Al Conductor

Cu Conductor

mm2

mm

mm

mm

mm

mm

kg/m

kg/m

Ω/km

Ω/km

25

6.0

2.5

0.1

2.0

34.6

1.13

1.58

1.2000

0.7270

35

6.9

2.5

0.1

2.1

36.8

1.29

1.92

0.8680

0.5240

50

8.2

2.5

0.1

2.2

39.8

1.51

2.36

0.6410

0.3870

70

9.7

2.5

0.1

2.3

43.2

1.81

3.04

0.4430

0.2680

95

11.3

2.5

0.1

2.4

46.9

2.17

3.87

0.3200

0.1930

120

12.8

2.5

0.1

2.4

50.1

2.53

4.69

0.2530

0.1530

150

14.2

2.5

0.1

2.5

53.3

2.90

5.60

0.2060

0.1240

185

15.9

2.5

0.1

2.6

57.2

3.40

6.77

0.1640

0.0991

240

18.3

2.6

0.1

2.8

63.2

4.12

8.55

0.1250

0.0754

300

20.4

2.8

0.1

3.0

69.0

4.89

10.46

0.1000

0.0601

400

23.2

3.0

0.1

3.4

76.7

6.10

13.18

0.0778

0.0470

500

26.4

3.2

0.1

3.6

85.7

8.10

16.55

0.0605

0.0366


7) 6/10(12)kV,6.35/11(12)kV,Three Cores,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable

Normal Cross Section of Conductor

Normal Diameter of Conductor

Normal Thickness of Insulation

Normal Thickness of
Copper Tape

Normal Thickness of Outer Sheath

Approx.
Overall Dia.

Approx. Net Weight

Max. D.C. Resistance of Conductor at 20ºC

Al Conductor

Cu Conductor

Al Conductor

Cu Conductor

mm2

mm

mm

mm

mm

mm

kg/m

kg/m

Ω/km

Ω/km

25

6.0

3.4

0.1

2.1

38.7

1.30

1.75

1.2000

0.7270

35

6.9

3.4

0.1

2.2

40.9

1.47

2.22

0.8680

0.5240

50

8.2

3.4

0.1

2.3

43.9

1.70

2.50

0.6410

0.3870

70

9.7

3.4

0.1

2.4

47.3

2.02

3.25

0.4430

0.2680

95

11.3

3.4

0.1

2.5

51.0

2.42

4.12

0.3200

0.1930

120

12.8

3.4

0.1

2.6

54.4

2.79

4.95

0.2530

0.1530

150

14.2

3.4

0.1

2.7

57.6

3.17

5.87

0.2060

0.1240

185

15.9

3.4

0.1

2.8

61.5

3.69

7.06

0.1640

0.0991

240

18.3

3.4

0.1

2.9

66.9

4.38

8.82

0.1250

0.0754

300

20.4

3.4

0.1

3.1

71.8

5.11

10.68

0.1000

0.0601

400

23.2

3.4

0.1

3.3

78.3

6.24

13.32

0.0778

0.0470

500

26.4

3.4

0.1

3.5

86.4

7.63

16.50

0.0605

0.0366


8) 8.7/10(15)kV,Three Cores,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable

Normal Cross Section of Conductor

Normal Diameter of Conductor

Normal Thickness of Insulation

Normal Thickness of
Copper Tape

Normal Thickness of Outer Sheath

Approx.
Overall Dia.

Approx. Net Weight

Max. D.C. Resistance of Conductor at 20ºC

Al Conductor

Cu Conductor

Al Conductor

Cu Conductor

mm2

mm

mm

mm

mm

mm

kg/m

kg/m

Ω/km

Ω/km

25

6.0

4.5

0.1

2.3

43.9

1.57

2.02

0.9270

0.7270

35

6.9

4.5

0.1

2.4

46.0

1.75

2.38

0.6680

0.5240

50

8.2

4.5

0.1

2.4

48.8

2.00

2.85

0.4936

0.3870

70

9.7

4.5

0.1

2.5

52.3

2.34

3.57

0.3420

0.2680

95

11.3

4.5

0.1

2.6

55.9

2.75

4.45

0.2464

0.1930

120

12.8

4.5

0.1

2.7

59.4

3.16

5.32

0.1955

0.1530

150

14.2

4.5

0.1

2.8

62.6

3.57

6.27

0.1587

0.1240

185

15.9

4.5

0.1

2.9

66.4

4.07

7.45

0.1271

0.0991

240

18.3

4.5

0.1

3.1

72.0

4.82

9.25

0.0976

0.0754

300

20.4

4.5

0.1

3.3

77.0

5.71

11.28

0.0778

0.0601

400

23.2

4.5

0.1

3.4

83.2

6.78

13.86

0.0615

0.0470

500

26.4

4.5

0.1

3.5

91.1

8.20

17.32

0.0487

0.0366


9) 12/20(24)kV, 12.7/22(24)kV,Three Cores,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable

Normal Cross Section of Conductor

Normal Diameter of Conductor

Normal Thickness of Insulation

Normal Thickness of
Copper Tape

Normal Thickness of Outer Sheath

Approx.
Overall Dia.

Approx. Net Weight

Max. D.C. Resistance of Conductor at 20ºC

Al Conductor

Cu Conductor

Al Conductor

Cu Conductor

mm2

mm

mm

mm2

mm

mm

kg/m

kg/m

Ω/km

Ω/km

25

-

 

 

 

 

 

 

 

 

35

6.9

5.5

0.1

2.4

50.3

2.00

2.63

0.8680

0.6680

50

8.2

5.5

0.1

2.5

53.3

2.26

3.11

0.6410

0.4936

70

9.7

5.5

0.1

2.6

56.8

2.62

3.85

0.4430

0.3420

95

11.3

5.5

0.1

2.8

60.6

3.07

4.77

0.3200

0.2464

120

12.8

5.5

0.1

2.9

64.1

3.49

5.65

0.2530

0.1955

150

14.2

5.5

0.1

3.0

67.3

3.91

6.61

0.2060

0.1587

185

15.9

5.5

0.1

3.1

71.2

4.44

7.81

0.1640

0.1271

240

18.3

5.5

0.1

3.3

76.8

5.21

9.64

0.1250

0.0976

300

20.4

5.5

0.1

3.3

81.3

6.10

11.66

0.1000

0.0778

400

23.2

5.5

0.1

3.5

87.7

7.20

14.28

0.0778

0.0615

500

26.4

5.5

0.1

3.8

96.0

9.15

17.80

0.0605

0.0487


10) 18/30(36)kV,19/33(36)kV,Three Cores,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable

Normal Cross Section of Conductor

Normal Diameter of Conductor

Normal Thickness of Insulation

Normal Thickness of
Copper Tape

Normal Thickness of Outer Sheath

Approx.
Overall Dia.

Approx. Net Weight

Max. D.C. Resistance of Conductor at 20ºC

Al Conductor

Cu Conductor

Al Conductor

Cu Conductor

mm2

mm

mm

mm

mm

mm

kg/m

kg/m

Ω/km

Ω/km

25

 

 

 

 

 

 

 

 

 

35

 

 

 

 

 

 

 

 

 

50

8.2

8.0

0.1

2.9

64.9

3.02

3.87

0.6410

0.4936

70

9.7

8.0

0.1

3.0

68.4

3.42

4.65

0.4430

0.3420

95

11.3

8.0

0.1

3.1

72.0

3.89

5.59

0.3200

0.2464

120

12.8

8.0

0.1

3.3

75.7

4.39

6.54

0.2530

0.1955

150

14.2

8.0

0.1

3.3

78.7

4.85

7.55

0.2060

0.1587

185

15.9

8.0

0.1

3.4

82.6

5.42

8.79

0.1640

0.1271

240

18.3

8.0

0.1

3.5

88.0

6.22

10.66

0.1250

0.0976

300

20.4

8.0

0.1

3.7

92.9

7.20

12.77

0.1000

0.0778

400

23.2

8.0

0.1

3.9

99.3

8.38

15.46

0.0778

0.0615

500

26.4

8.0

0.1

4.2

107.6

10.15

18.85

0.0605

0.0487
Medium Voltage 6/35KV XLPE Insulated Unarmoured Power Cable

Application:
Media Voltage XLPE Insulated power cable is used to transmit and distribute power in power transmission and distribution system of 35kV or lower. It is generally applied to the fields including power, construction, mines, metallurgy, petrochemical industry and communication in complete replace of oil immersed paper insulated power cable.

Property:
1.The highest allowed operating temperature of conductor for long-term working is 90 degrees.
2.In short circuit (Max long term is no more than 5 seconds). The highest temperature for conductor is no more than 250 degrees.
3.The cable is laid without horizontal drop limit. The environment temperature should be no lower than 0 when lay. Otherwise it should be preheated.
4.Excellent electrical performance, resistance to chemical corrosion.
5.They can stand advisable traction when laid.They can stand traction from Outside.Left low smoke halogen-free after burned.Retard the burning of the cable.

Specification:

Standard:
IEC60502,designing and manufacturing special power cable according to the other standards required by the customers.
1) 3.6/6(7.2)kV,3.6/6.6(7.2)kV,Single Core,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable

Normal Cross Section of Conductor

Normal Diameter of Conductor

Normal Thickness of Insulation

Normal Thickness of
Copper Tape

Normal Thickness of Outer Sheath

Approx.
Overall Dia.

Approx. Net Weight

Max. D.C. Resistance of Conductor at 20ºC

Al Conductor

Cu Conductor

Al Conductor

Cu Conductor

mm2

mm

mm

mm

mm

mm

kg/m

kg/m

Ω/km

Ω/km

25

6.0

2.5

0.12

1.5

17.6

0.34

0.49

1.2000

0.7270

35

7.0

2.5

0.12

1.5

18.5

0.39

0.60

0.8680

0.5240

50

8.3

2.5

0.12

1.6

20.0

0.46

0.74

0.6410

0.3870

70

9.7

2.5

0.12

1.6

21.5

0.55

0.96

0.4430

0.2680

95

11.3

2.5

0.12

1.7

23.3

0.66

1.23

0.3200

0.1930

120

13

2.5

0.12

1.7

24.8

0.77

1.48

0.2530

0.1530

150

14.6

2.5

0.12

1.8

26.4

0.87

1.77

0.2060

0.1240

185

15.9

2.5

0.12

1.8

28.1

1.01

2.13

0.1640

0.0991

240

18.3

2.6

0.12

1.9

30.9

1.23

2.71

0.1250

0.0754

300

20.4

2.8

0.12

2.0

33.6

1.48

3.32

0.1000

0.0601

400

23.2

3.0

0.12

2.1

37.0

1.81

4.16

0.0778

0.0470

500

26.4

3.2

0.12

2.2

41.1

2.24

5.27

0.0605

0.0366

630

30.1

3.2

0.12

2.3

45.0

2.73

6.62

0.0469

0.0283


2) 6/10(12)kV,6.35/11(12)kV,Single Core,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable

Normal Cross Section of Conductor

Normal Diameter of Conductor

Normal Thickness of Insulation

Normal Thickness of
Copper Tape

Normal Thickness of Outer Sheath

Approx.
Overall Dia.

Approx. Net Weight

Max. D.C. Resistance of Conductor at 20ºC

Al Conductor

Cu Conductor

Al Conductor

Cu Conductor

mm2

mm

mm

mm

mm

mm

kg/m

kg/m

Ω/km

Ω/km

25

6.0

3.4

0.12

1.5

19.4

0.40

0.55

1.2000

0.7270

35

6.9

3.4

0.12

1.6

20.5

0.45

0.66

0.8680

0.5240

50

8.2

3.4

0.12

1.6

21.8

0.52

0.80

0.6410

0.3870

70

9.7

3.4

0.12

1.7

23.5

0.62

1.03

0.4430

0.2680

95

11.3

3.4

0.12

1.7

25.1

0.73

1.30

0.3200

0.1930

120

12.8

3.4

0.12

1.8

26.8

0.85

1.56

0.2530

0.1530

150

14.2

3.4

0.12

1.8

28.2

0.95

1.85

0.2060

0.1240

185

15.9

3.4

0.12

1.9

30.1

1.10

2.22

0.1640

0.0991

240

18.3

3.4

0.12

2.0

32.7

1.33

2.80

0.1250

0.0754

300

20.4

3.4

0.12

2.0

34.8

1.54

3.39

0.1000

0.0601

400

23.2

3.4

0.12

2.2

38.0

1.87

4.22

0.0778

0.0470

500

26.4

3.4

0.12

2.2

41.5

2.26

5.29

0.0605

0.0366

630

30.1

3.4

0.12

2.4

45.6

2.78

6.67

0.0469

0.0283


3) 8.7/10(15)kV,Single Core,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable

Normal Cross Section of Conductor

Normal Diameter of Conductor

Normal Thickness of Insulation

Normal Thickness of
Copper Tape

Normal Thickness of Outer Sheath

Approx.
Overall Dia.

Approx. Net Weight

Max. D.C. Resistance of Conductor at 20ºC

Al Conductor

Cu Conductor

Al Conductor

Cu Conductor

mm2

mm

mm

mm

mm

mm

kg/m

kg/m

Ω/km

Ω/km

25

6.0

4.5

0.12

1.6

21.8

0.48

0.63

1.2000

0.7270

35

6.9

4.5

0.12

1.7

22.9

0.54

0.75

0.8680

0.5240

50

8.2

4.5

0.12

1.7

24.2

0.61

0.89

0.6410

0.3870

70

9.7

4.5

0.12

1.8

25.9

0.72

1.13

0.4430

0.2680

95

11.3

4.5

0.12

1.8

27.5

0.84

1.40

0.3200

0.1930

120

12.8

4.5

0.12

1.9

29.2

0.96

1.67

0.2530

0.1530

150

14.2

4.5

0.12

1.9

30.6

1.06

1.96

0.2060

0.1240

185

15.9

4.5

0.12

2.0

32.5

1.22

2.34

0.1640

0.0991

240

18.3

4.5

0.12

2.1

35.1

1.46

2.93

0.1250

0.0754

300

20.4

4.5

0.12

2.1

37.2

1.68

3.52

0.1000

0.0601

400

23.2

4.5

0.12

2.2

40.2

2.00

4.35

0.0778

0.0470

500

26.4

4.5

0.12

2.3

43.9

2.43

5.45

0.0605

0.0366

630

30.1

4.5

0.12

2.4

47.8

2.93

6.83

0.0469

0.0283


4) 12/20(24)kV, 12.7/22(24)kV,Single Core,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable

Normal Cross Section of Conductor

Normal Diameter of Conductor

Normal Thickness of Insulation

Normal Thickness of
Copper Tape

Normal Thickness of Outer Sheath

Approx.
Overall Dia.

Approx. Net Weight

Max. D.C. Resistance of Conductor at 20ºC

Al Conductor

Cu Conductor

Al Conductor

Cu Conductor

mm2

mm

mm

mm

mm

mm

kg/m

kg/m

Ω/km

Ω/km

25

 

 

 

 

 

 

 

 

 

35

6.9

5.5

0.12

1.7

24.9

0.62

0.83

0.8680

0.5240

50

8.2

5.5

0.12

1.8

26.4

0.70

0.98

0.6410

0.3870

70

9.7

5.5

0.12

1.8

27.9

0.80

1.21

0.4430

0.2680

95

11.3

5.5

0.12

1.9

29.7

0.94

1.50

0.3200

0.1930

120

12.8

5.5

0.12

1.9

31.2

1.05

1.77

0.2530

0.1530

150

14.2

5.5

0.12

2.0

32.8

1.17

2.07

0.2060

0.1240

185

15.9

5.5

0.12

2.0

34.5

1.33

2.45

0.1640

0.0991

240

18.3

5.5

0.12

2.1

37.1

1.57

3.04

0.1250

0.0754

300

20.4

5.5

0.12

2.2

39.4

1.81

3.66

0.1000

0.0601

400

23.2

5.5

0.12

2.3

42.4

2.14

4.49

0.0778

0.0470

500

26.4

5.5

0.12

2.4

46.1

2.58

5.61

0.0605

0.0366

630

30.1

5.5

0.12

2.4

49.8

3.10

6.99

0.0469

0.0283


5) 18/30(36)kV,19/33(36)kV,Single Core,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable

Normal Cross Section of Conductor

Normal Diameter of Conductor

Normal Thickness of Insulation

Normal Thickness of
Copper Tape

Normal Thickness of Outer Sheath

Approx.
Overall Dia.

Approx. Net Weight

Max. D.C. Resistance of Conductor at 20ºC

Al Conductor

Cu Conductor

Al Conductor

Cu Conductor

mm2

mm

mm

mm

mm

mm

kg/m

kg/m

Ω/km

Ω/km

25

 

 

 

 

 

 

 

 

 

35

 

 

 

 

 

 

 

 

 

50

8.2

8.0

0.12

2.0

31.8

0.95

1.23

0.6410

0.3870

70

9.7

8.0

0.12

2.0

33.3

1.07

1.47

0.4430

0.2680

95

11.3

8.0

0.12

2.1

35.1

1.21

1.78

0.3200

0.1930

120

12.8

8.0

0.12

2.1

36.6

1.34

2.05

0.2530

0.1530

150

14.2

8.0

0.12

2.2

38.2

1.47

2.37

0.2060

0.1240

185

15.9

8.0

0.12

2.2

39.9

1.64

2.76

0.1640

0.0991

240

18.3

8.0

0.12

2.3

42.5

1.90

3.37

0.1250

0.0754

300

20.4

8.0

0.12

2.4

44.8

2.16

4.01

0.1000

0.0601

400

23.2

8.0

0.12

2.4

47.6

2.52

4.87

0.0778

0.0470

500

26.4

8.0

0.12

2.5

51.3

2.98

6.01

0.0605

0.0366

630

30.1

8.0

0.12

2.6

55.2

3.54

7.43

0.0469

0.0283


6) 3.6/6(7.2)kV,3.6/6.6(7.2)kV,Three Cores,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable

Normal Cross Section of Conductor

Normal Diameter of Conductor

Normal Thickness of Insulation

Normal Thickness of
Copper Tape

Normal Thickness of Outer Sheath

Approx.
Overall Dia.

Approx. Net Weight

Max. D.C. Resistance of Conductor at 20ºC

Al Conductor

Cu Conductor

Al Conductor

Cu Conductor

mm2

mm

mm

mm

mm

mm

kg/m

kg/m

Ω/km

Ω/km

25

6.0

2.5

0.1

2.0

34.6

1.13

1.58

1.2000

0.7270

35

6.9

2.5

0.1

2.1

36.8

1.29

1.92

0.8680

0.5240

50

8.2

2.5

0.1

2.2

39.8

1.51

2.36

0.6410

0.3870

70

9.7

2.5

0.1

2.3

43.2

1.81

3.04

0.4430

0.2680

95

11.3

2.5

0.1

2.4

46.9

2.17

3.87

0.3200

0.1930

120

12.8

2.5

0.1

2.4

50.1

2.53

4.69

0.2530

0.1530

150

14.2

2.5

0.1

2.5

53.3

2.90

5.60

0.2060

0.1240

185

15.9

2.5

0.1

2.6

57.2

3.40

6.77

0.1640

0.0991

240

18.3

2.6

0.1

2.8

63.2

4.12

8.55

0.1250

0.0754

300

20.4

2.8

0.1

3.0

69.0

4.89

10.46

0.1000

0.0601

400

23.2

3.0

0.1

3.4

76.7

6.10

13.18Our home used electric appliances have various kinds of products. The most popular are our blenders. They are popular in South America, the Middle East and Southeast Asia. The home used Electric Blender can divided into two classified: The push button models and the rotatory switch button models. The push button blenders have one speed to eight speeds options. And the rotatory switch button have one to four speeds option. Accroding to the user's requirement, can choose differnece speed to handle the fruit or vegetable. Some blenders also can use the filter, to seperate the juice and the flesh. Beside the blending function, another function is grinding. Our blenders also attached with the grinder. Some grinders can use for making the peper and sesame power. Some grinders can make the breadcrumbs and shred the dried cheese.User can combine in any way they want. The most important is that we can control the the motor quanlity directly. Because we produce Blender motors by ourself. Also by manufacturing our own plastic molds, we ensure exceptional product features, such as high impact resistance, high heat distortion, high gloss and good base resin colors.

Blender

Electric Blender,Hand Blender,Smoothie Blender,Hand Electric Mixer,Juice Blender

Jiangmen Yingxiang Motor Manufacturer Co., Ltd. , http://www.yingxiang-blender.com